MOLAS B300 - BANKABLE REMOTE SENSING DOPPLER WIND LIDAR SYSTEMS - ONSHORE & OFFSHORE PROJECTS

Molas B300 - Bankable Remote Sensing Doppler Wind LiDAR Systems - Onshore & Offshore Projects

Molas B300 - Bankable Remote Sensing Doppler Wind LiDAR Systems - Onshore & Offshore Projects

Blog Article



The Molas B300 Remote Sensing Doppler wind LiDAR was produced by Movelaser , centered on all-fiber coherent doppler effect, through the 4-beam VAD scanning vector synthesis technology, can measure wind speed and direction in 30-300 m above the lidar. Additionally, air temperature, humidity and other parameters could be measured by the sensor module. Molas B300 has the characteristics of high precision, stable system performance, maintenance friendly and data security.

It has been tested by DNV-GL (Type specification classification test and independent performance test), WINDGUARD and DTU. Molas B300 onshore wind LiDAR may be sent applications for onshore and offshore Wind Resource Assessment (WRA), Power Curve Validation (PCV), Wind Power Prediction system, operation management of wind farm, atmospheric physics research, weather forecast, etc.

The four core modules of Molas B300, including fiber lidar emitter, laser transceiver system, high-speed data acquisition system, data processing softwareare independently produced by Movelaser. The core modules, which have a top degree of matching and ensure the unified coordination and data information security of the entire machine system, have reached international advanced level.

Certification and Calibration Reports of Molas B300 Doppler Wind LiDAR

DNV-GL has conducted an unbiased classification assessment of three lidar units of type MOLAS B300 doppler wind LiDAR according to the IEC 61400-12-1 Ed. 2 [4].

The classification measurement campaigns took place over two sites, with one Lidar deployed at two different sites and another lidar deployed at one site, so a total of three separate campaigns were analysed. DNV was in charge of conducting all three classfication campaigns. The initial and the second classification campaigns took place at the Hamburg and Janneby test site to classify the unit MOLAS B300-117 [1] [2]. The next classification campaign took place also in Hamburg to classify the second unit MOLAS B300-202 [3].

In the report, a summary of all classification task assessments of the kind MOLAS B300 lidar are shown in the picture left, and the type-specific class and standard uncertaintity of Molas B300 are average 2.4% and 1.4% respectively.

Click Here to obtain more information about Movelaser.

Report this page